Heat pump / air conditioner (up to 5 indoor units)MULTI SPLIT MXZ
The price depends on the configuration and installation conditions – an EKO2 specialist prepares a quotation covering equipment, works and commissioning.
Heat pump / air conditioner (up to 5 indoor units) MULTI SPLIT MXZ
The distinctive feature of Multi Split is its versatility, making the most of the possibilities for creating a perfect indoor climate. Several indoor units can be connected to a single outdoor unit, keeping even very large spaces fresh in summer and pleasantly warm in winter. You can choose from as many as 12 different indoor unit models (wall-mounted, floor-standing, cassette, ducted, ceiling-suspended). Everything is designed for your optimum comfort. Having chosen individual indoor units of the preferred model, only one outdoor unit is installed outside. You decide what temperature should be in the bedrooms, kitchen or living room, and you can set the fan speed and other parameters on each floor or in each room.
What we check before quoting
Assess whether all rooms will need full capacity at once, and compare with separate singles: Multi Split saves space, separate systems are independent of each other.
Models
Select models to compare (up to 4).
Technical data
| Data | |
|---|---|
| Rated heating capacity (kW) | 3.2 |
| Rated cooling capacity (kW) | 2.5 |
| Airflow (m³/min) | 4.9-5.9-7.3-8.9-12.9 |
| Noise level heating/cooling (dB(A)) | 19-24-34-39-45 |
| Dimensions (mm) H×L×W | 299 x 798 x 219 |
| Weight (kg) | 10.5 |
Vidiniai įrenginiai gali būti derinami su visais Multi Split įrenginiais (prie vieno išorinio įrenginio jungti kelis vidinius įrenginius).
| Data | |
|---|---|
| Rated heating capacity (kW) | 4.0 |
| Rated cooling capacity (kW) | 3.2 |
| Airflow (m³/min) | 6.5-7.5-8.5 |
| Noise level (dB(A)) | 25-28-31 |
| Dimensions (mm) H×L×D | 245x570x570 |
| Dimensions (mm) decorative panel | 10x625x625 |
| Weight (kg) unit / decorative panel | 15/3 |
Vidiniai įrenginiai gali būti derinami su visais Multi Split įrenginiais (prie vieno išorinio įrenginio jungti kelis vidinius įrenginius).
| Heating | |
|---|---|
| Supported number of indoor units | Iki 2 vidinių įrenginių |
| Economical heating, °C | -15* |
| SCOP / Energy class | 4/A+ |
| Heating capacity (kW) (nom. (min.–max.)) | 4(1.0-4.1) |
| P design, heating (kW) | 2.7 |
| Annual electricity consumption (kWh/a) | 944 |
| Cooling | |
| SEER / Energy class | 6.1/A++ |
| Cooling capacity (kW) (min.–max.) | 3.3 (1.1-3.8) |
| P design, cooling (kW) | 3.3 |
| Annual electricity consumption (kWh/a) | 189 |
| Data | |
| Dimensions (mm) Height x Length x Width | 550x800x285 |
| Weight (kg) | 33 |
| Noise level (dB(A)) cooling/heating | 49-50 |
| Recommended fuse (A) | 13 |
| Maximum operating current (A) | 10 |
| Pipe diameter (liquid/gas) (in) | 2 x 1/4” ,2 x 3/8” |
| Maximum total pipe length (m) | 20 |
| Maximum height difference (m) | 10 |
| Power supply voltage | 230/1/50 |
| Refrigerant / charge (kg) | R32/0.8 |
*Papildomai instaliavus pakaitinimo kabelį MAC-AUTO3-1,5, garantuotas ekonomiškas šilumos tiekimas iki -20°C lauko temperatūros. ! Suteikiama 5 metų garantija, jei įrangos montavimą atliko sertifikuoti montuotojai.
| Heating | |
|---|---|
| Supported number of indoor units | Iki 2 vidinių įrenginių |
| Economical heating (°C) | -15* |
| SCOP / Energy class | 4.6/A++ |
| Heating capacity (kW) (nom. (min.–max.)) | 4.5(1.0-4.8) |
| P design, heating (kW) | 3.5 |
| Annual electricity consumption (kWh/a) | 1065 |
| Cooling | |
| SEER / Energy class | 8.7/A+++ |
| Cooling capacity (kW) (min.–max.) | 4.2(1.1-4.4) |
| P design, cooling (kW) | 4.2 |
| Annual electricity consumption (kWh/a) | 169 |
| Data | |
| Dimensions (mm) Height x Length x Width | 800 x 550 x 285 |
| Weight (kg) | 37 |
| Noise level (dB(A)) cooling/heating | 44/50 |
| Recommended fuse (A) | 16 |
| Maximum operating current (A) | 12.2 |
| Pipe diameter (liquid/gas) (in) | 2 x 1/4” ,2 x 3/8” |
| Maximum total pipe length (m) | 30 |
| Maximum height difference (m) | 15(15) |
| Power supply voltage | 230/1/50 |
| Refrigerant / charge (kg) | R32/0.8 |
*Papildomai instaliavus pakaitinimo kabelį MAC-AUTO3-1,5, garantuotas ekonomiškas šilumos tiekimas iki -20°C lauko temperatūros. ! Suteikiama 5 metų garantija, jei įrangos montavimą atliko sertifikuoti montuotojai.
| Heating | |
|---|---|
| Supported number of indoor units | Iki 2 vidinių įrenginių |
| Economical heating (°C) | -20 |
| SCOP / Energy class | A+/4.5 |
| Heating capacity (kW) (nom. (min.–max.)) | 6.4(1.0-7.0) |
| P design, heating (kW) | 3.5 |
| Annual electricity consumption (kWh/a) | 1089 |
| Cooling | |
| SEER / Energy class | 8.63 /A+++ |
| Cooling capacity (kW) (min.–max.) | 5.3 (1.1-5.6) |
| P design, cooling (kW) | 5.3 |
| Annual electricity consumption (kWh/a) | 216 |
| Data | |
| Dimensions (mm) Height x Length x Width | 800 x 550 x 285 |
| Weight (kg) | 38 |
| Noise level (dB(A)) cooling/heating | 46-51 |
| Maximum operating current (A) | 12.2 |
| Recommended fuse (A) | 16 |
| Pipe diameters (mm) gas/liquid | 2 x 3/8” ,2 x 1/4” |
| Maximum total pipe length (m) | 30 |
| Maximum height difference (m) | 15(15) |
| Power supply voltage | 230/1/50 |
| Refrigerant / charge (kg) | R32/1.0 |
! Suteikiama 5 metų garantija, jei įrangos montavimą atliko sertifikuoti montuotojai.
| Heating | |
|---|---|
| Supported number of indoor units | Iki 2 vidinių įrenginių |
| Hyper Heating technology ✓ | |
| Economical heating, °C | -25 |
| SCOP / Energy class | 4.1 /A+ |
| Heating capacity (kW) (nom. (min.–max.)) | 6.4 (1.0-7.0) |
| P design, heating (kW) | 6.4 |
| Annual electricity consumption (kWh/a) | 2172 |
| Cooling | |
| SEER / Energy class | 6.8/A++ |
| P design, cooling (kW) | 5.3 |
| Annual electricity consumption (kWh/a) | 274 |
| Cooling capacity (kW) (min.–max.) | 5.3 (1.1-6.0) |
| Data | |
| Dimensions (mm) Height x Length x Width | 796 x 950 x 330 |
| Weight (kg) | 61 |
| Noise level (dB(A)) cooling/heating | 45-47 |
| Recommended fuse (A) | 16 |
| Maximum operating current (A) | 15.6 |
| Pipe diameters (mm) gas/liquid | 2 x 3/8” ,2 x 1/4” |
| Maximum total pipe length (m) | 30 |
| Maximum height difference (m) | 15 |
| Power supply voltage | 230/1/50 |
| Refrigerant / charge (kg) | R32/2.4 |
! Suteikiama 5 metų garantija, jei įrangos montavimą atliko sertifikuoti montuotojai.
| Heating | |
|---|---|
| Supported number of indoor units | Iki 3 vidinių įrenginių |
| Economical heating (°C) | -15* |
| SCOP / Energy class | 4.6/A++ |
| Heating capacity (kW) (nom. (min.–max.)) | 7.0 (2.6-9.0) |
| P design, heating (kW) | 5.2 |
| Annual electricity consumption (kWh/a) | 1583 |
| Cooling | |
| SEER / Energy class | 8.5/A+++ |
| Cooling capacity (kW) (min.–max.) | 5.4 (1.9-6.8) |
| P design, cooling (kW) | 5.4 |
| Annual electricity consumption (kWh/a) | 222 |
| Data | |
| Dimensions (mm) Height x Length x Width | 710x840x330 |
| Weight (kg) | 58 |
| Noise level (dB(A)) cooling/heating | 46-50 |
| Recommended fuse (A) | 25 |
| Maximum operating current (A) | 18.0 |
| Pipe diameters (mm) gas/liquid | 3 x 3/8” ,3 x 1/4” |
| Maximum total pipe length (m) | 50 |
| Maximum height difference (m) | 15(15) |
| Power supply voltage | 230/1/50 |
| Refrigerant / charge (kg) | R32/2.4 |
*Papildomai instaliavus pakaitinimo kabelį MAC-AUTO3-1,5, garantuotas ekonomiškas šilumos tiekimas iki -20°C lauko temperatūros. ! Suteikiama 5 metų garantija, jei įrangos montavimą atliko sertifikuoti montuotojai.
| Heating | |
|---|---|
| Supported number of indoor units | Iki 4 vidinių įrenginių |
| Economical heating (°C) | -15* |
| SCOP / Energy class | 4.1/A+ |
| Heating capacity (kW) (nom. (min.–max.)) | 8.6 (3.4-10.7) |
| P design, heating (kW) | 7.0 |
| Annual electricity consumption (kWh/a) | 2389 |
| Cooling | |
| SEER / Energy class | 8.1/A++ |
| Annual electricity consumption (kWh/a) | 311 |
| P design, cooling (kW) | 7.2 |
| Cooling capacity (kW) (min.–max.) | 7.2 (3.7-8.8) |
| Data | |
| Dimensions (mm) Height x Length x Width | 796x950x330 |
| Weight (kg) | 59 |
| Noise level (dB(A)) cooling/heating | 48-54 |
| Recommended fuse (A) | 25 |
| Maximum operating current (A) | 18.0 |
| Pipe diameters (mm) gas/liquid | 1 x 1/2” ,3 x 3/8” ,4 x 1/4” |
| Maximum total pipe length (m) | 60 |
| Maximum height difference (m) | 15(15) |
| Power supply voltage | 230/1/50 |
| Refrigerant / charge (kg) | R32/2.4 |
*Papildomai instaliavus pakaitinimo kabelį MAC-AUTO3-1,5, garantuotas ekonomiškas šilumos tiekimas iki -20°C lauko temperatūros. ! Suteikiama 5 metų garantija, jei įrangos montavimą atliko sertifikuoti montuotojai.
| Heating | |
|---|---|
| Supported number of indoor units | Iki 5 vidinių įrenginių |
| Economical heating (°C) | -15* |
| SCOP / Energy class | 4.6/A++ |
| Heating capacity (kW) (nom. (min.–max.)) | 10.5 (4.1-14.0) |
| P design, heating (kW) | 7.4 |
| Annual electricity consumption (kWh/a) | 2205 |
| Cooling | |
| SEER / Energy class | 8.2/A++ |
| Cooling capacity (kW) (min.–max.) | 10.2 (3.9-11.0) |
| P design, cooling (kW) | 10.2 |
| Annual electricity consumption (kWh/a) | 436 |
| Data | |
| Dimensions (mm) Height x Length x Width | 796 x 950 x 330 |
| Weight (kg) | 62 |
| Noise level (dB(A)) cooling/heating | 52-56 |
| Maximum operating current (A) | 21.4 |
| Recommended fuse (A) | 25 |
| Pipe diameters (mm) gas/liquid | 1 x 1/2” ,4 x 3/8” ,5 x 1/4” |
| Maximum total pipe length (m) | 80 |
| Maximum height difference (m) | 15 |
| Power supply voltage | 230/1/50 |
| Economical heating (°C) | -15 |
| Refrigerant / charge (kg) | R32/2.4 |
*Papildomai instaliavus pakaitinimo kabelį MAC-AUTO3-1,5, garantuotas ekonomiškas šilumos tiekimas iki -20°C lauko temperatūros. ! Suteikiama 5 metų garantija, jei įrangos montavimą atliko sertifikuoti montuotojai.
Data comes from the EKO2ŠILUMA product database based on manufacturer documentation. Before ordering, we check the current manufacturer specification.
See how it works
MULTI SPLIT MXZ – 3D diagram
Interactive model: rotate, zoom, click on components.
Compatible with
Indoor and outdoor unit combinations are confirmed by an EKO2 engineer according to the manufacturer’s compatibility tables.
Documents
Installation and commissioning
Where already installed
Descriptions of completed projects with this equipment are published with the client’s consent. Projects
FAQ
Why choose an air-to-air heat pump?
An air-to-air heat pump combines three functions in one system: heating in winter, cooling in summer and air filtration. It can be fitted in an occupied home or a new build, and both the outdoor and indoor units take up little space.
It works well alongside existing heating – electric heaters, a fireplace, a stove or a gas boiler – and takes over much of the heating load in spring and autumn. Some series, such as MSZ-LN, have a more advanced filter system; see the product page for the exact features. We will match the right model to your rooms through the system finder.
Why choose an air-to-water heat pump?
If you own or are building a house with a wet heating system (underfloor heating, radiators) and need domestic hot water, an air-to-water heat pump can be a complete, year-round heat source. No fuel storage, chimney or boiler-room upkeep – you control the temperature from a controller or an app.
MITSUBISHI ELECTRIC ECODAN all-in-one units have an integrated cylinder, while Hydro-box versions connect to a separate cylinder designed for heat pumps. In summer the system prepares hot water. Which configuration suits you is explained in our guide Air-to-air or air-to-water.
Does a heat pump work below −25 °C, and does it harm the unit?
A heat pump keeps working at very low temperatures, but its heat output and efficiency fall. The exact operating limits of each model, per manufacturer data, are on the product page – e.g. MSZ-LN-VGHZ with Hyper Heating or the ZUBADAN PUHZ-SHW series. Operating limit and guaranteed capacity are not the same thing – we explain this in Heat pumps for the Lithuanian climate.
Do not switch the heat pump off during hard frosts: starting a cold system at −25 °C or below is not ideal, while continuous operation is easier on the compressor.
Can a heat pump be combined with my existing heating?
Yes. An air-to-air heat pump is often installed as an additional heat source alongside electric heating, a fireplace or a gas boiler. An air-to-water system can be integrated into an existing wet heating system; we then assess the radiator or underfloor flow temperature, hydraulics and controls. For efficient operation, the existing system must be in good order and temperature sensors must work correctly. Start with the system finder.
Get a quotation for MULTI SPLIT MXZ
An engineer will check whether this model suits your building, select the capacity and prepare a quotation including installation and commissioning.







.webp)
.webp)