Air-to-water

Power Inverter heat pumpPUD-SWM

40 dB(A)quietest mode
A+++energy class
Models

The price depends on the configuration and installation conditions – an EKO2 specialist prepares a quotation covering equipment, works and commissioning.

Suitable for

Power Inverter heat pump PUD-SWM

Thanks to state-of-the-art technologies and a high-performance compressor, the new PUD-SWM units offer outstanding technical characteristics and can produce water at up to +60°C! PUD-SWM series heat pumps are market leaders in seasonal efficiency and heat output at very low ambient temperatures.

EKO2 engineer's notes
  • We size the capacity based on heat losses and room use, not on floor area alone.
  • We assess the indoor and outdoor unit locations, pipe run length, condensate drainage and electrical supply capacity.
  • Start-up and commissioning are carried out according to the manufacturer’s instructions – this is important for the warranty.

Models

Select models to compare (up to 4).

Technical data

Data
System typeSplit
Hot water cylinder (l)300
Energy class, heating / W35ºCA+++
ClassA
Sound power level (PWL)40
Electric heater (kW)9 (3+6)
Dimensions (mm) (length x height x depth)595 x 2050 x 680
Minimum room height required to install the unit (mm)2250
Weight (empty – without water) (kg)116
Weight (full – with water) (kg)425
Max. flow temp. (°C)60
Min. flow temp. (°C)20
Fuse / heater (A)3 x 16
Voltage (V/Ph/Hz)400/3/50
Operating current13
Min.–max. temp. setting (°C)0 - 35
Guaranteed indoor temperature °C10 - 30

EHST30D-YM9D page

Data comes from the EKO2ŠILUMA product database based on manufacturer documentation. Before ordering, we check the current manufacturer specification.

EKO2 CLIMATE LAB

See how it works

PUD-SWM – 3D diagram

Interactive model: rotate, zoom, click on components.

Compatible with

Indoor and outdoor unit combinations are confirmed by an EKO2 engineer according to the manufacturer’s compatibility tables.

Documents

Installation and commissioning

InspectionWe assess the location, pipe run and electrics
QuotationEquipment, works, materials, VAT
InstallationCertified installers
CommissioningCommissioning and handover briefing
ServiceEquipment passport in MANO EKO2

Where already installed

Descriptions of completed projects with this equipment are published with the client’s consent. Projects

Quick enquiry

Leave your number – an engineer will call you back during working hours.

FAQ

Why choose an air-to-air heat pump?

An air-to-air heat pump combines three functions in one system: heating in winter, cooling in summer and air filtration. It can be fitted in an occupied home or a new build, and both the outdoor and indoor units take up little space.

It works well alongside existing heating – electric heaters, a fireplace, a stove or a gas boiler – and takes over much of the heating load in spring and autumn. Some series, such as MSZ-LN, have a more advanced filter system; see the product page for the exact features. We will match the right model to your rooms through the system finder.

Why choose an air-to-water heat pump?

If you own or are building a house with a wet heating system (underfloor heating, radiators) and need domestic hot water, an air-to-water heat pump can be a complete, year-round heat source. No fuel storage, chimney or boiler-room upkeep – you control the temperature from a controller or an app.

MITSUBISHI ELECTRIC ECODAN all-in-one units have an integrated cylinder, while Hydro-box versions connect to a separate cylinder designed for heat pumps. In summer the system prepares hot water. Which configuration suits you is explained in our guide Air-to-air or air-to-water.

Does a heat pump work below −25 °C, and does it harm the unit?

A heat pump keeps working at very low temperatures, but its heat output and efficiency fall. The exact operating limits of each model, per manufacturer data, are on the product page – e.g. MSZ-LN-VGHZ with Hyper Heating or the ZUBADAN PUHZ-SHW series. Operating limit and guaranteed capacity are not the same thing – we explain this in Heat pumps for the Lithuanian climate.

Do not switch the heat pump off during hard frosts: starting a cold system at −25 °C or below is not ideal, while continuous operation is easier on the compressor.

Can a heat pump be combined with my existing heating?

Yes. An air-to-air heat pump is often installed as an additional heat source alongside electric heating, a fireplace or a gas boiler. An air-to-water system can be integrated into an existing wet heating system; we then assess the radiator or underfloor flow temperature, hydraulics and controls. For efficient operation, the existing system must be in good order and temperature sensors must work correctly. Start with the system finder.

Get a quotation for PUD-SWM

An engineer will check whether this model suits your building, select the capacity and prepare a quotation including installation and commissioning.

EKO2 ASSISTANTAnswers based on EKO2 product data. The final decision is confirmed by an engineer.
Hello! Choose a question below or write your own – I will answer from the EKO2 knowledge base.