Indoor unit
VL-80U5-E
Model family: Lossnay wall-mounted mini heat recovery unit VL-80U5-E
80 m³/horo srautas
37 dB(A)noise
Technical data
| Data | |
|---|---|
| Controls | Virvele |
| Dimensions (mm) H×L×W | 265x620x200 |
| Weight (kg) | 6.7 |
| Power supply voltage | 230V/1/50Hz |
| Wall opening diameter (mm) | 85x2 |
| Pipe diameter (mm) | 70*2 |
| Installation | Horizontaliai |
| Operating mode – high (High) | |
| Airflow (m³/h) | 80 |
| Temperature exchange efficiency (%) | 70 |
| Noise level (dB(A)) | 37 |
| Power input (W) | 28 |
| Operating mode – low (Low) | |
| Airflow (m³/h) | 49 |
| Temperature exchange efficiency (%) | 70 |
| Noise level (dB(A)) | 26 |
| Power input (W) | 15.5 |
Atliekame mini rekuperacinės sistemos montavimą.
Documents
Specification text for the project
For architects and designers: copy the verified model specification.
Create specificationSee how it works
VL-80U5-E – 3D
Interactive model: rotate, zoom, click on components.
Start your climate project