Heat pump / air conditioner for warehousesIDH-D
The price depends on the configuration and installation conditions – an EKO2 specialist prepares a quotation covering equipment, works and commissioning.







Heat pump / air conditioner for warehouses IDH-D
IDH series heat pump indoor units are designed for efficient heating/cooling of dirty, dusty production, storage or other premises.
- We size the capacity based on heat losses and room use, not on floor area alone.
- We assess the indoor and outdoor unit locations, pipe run length, condensate drainage and electrical supply capacity.
- Start-up and commissioning are carried out according to the manufacturer’s instructions – this is important for the warranty.
Models
Select models to compare (up to 4).
Technical data
| Data | |
|---|---|
| Heating, min.–max. capacity (kW) | 5.0-16.0 |
| Cooling, min.–max. capacity (kW) | 5.5-14.0 |
| Dimensions Height x Length x Width (mm) | 263x1443x886 |
| Weight (kg) | 42 |
| Number of fans (pcs) | 2 |
| Airflow (m³/h) | 2750 |
| Air throw without EYO hood / with EYO hood (m) | 6 />8 |
| Noise level (SPL)* (dB(A)) | 45/41 |
| Power supply (V/Hz) | 230/50 |
| Maximum operating current (A) | 1.46 |
| Fan power input (W) | 80 |
| Pipe diameter (in) | 3/8" - 5/8" |
| Condensate pipe diameter (in) | 3/4" |
| Max. pipe length (m) | 30 |
| Minimum intake temperature (°C) | +10 |
| Evaporator wall clearance (mm) | 4 |
| Protection class (IP) | 44 |
| Refrigerant | R410A / R32 |
*Triukšmo lygis išmatuotas tuščioje patalpoje
| Data | |
|---|---|
| Heating, min.–max. capacity (kW) | 12.5-25.0 |
| Cooling, min.–max. capacity (kW) | 5.5-14.0 |
| Dimensions Height x Length x Width (mm) | 263x1443x886 |
| Weight (kg) | 45 |
| Number of fans (pcs) | 2 |
| Airflow (m³/h) | 2750 |
| Air throw without EYO hood / with EYO hood (m) | 6 />8 |
| Noise level (SPL)* (dB(A)) | 45/41 |
| Power supply (V/Hz) | 230/50 |
| Maximum operating current (A) | 1.46 |
| Fan power input (W) | 80 |
| Pipe diameter (in) | 3/8” - 1 1/8” |
| Condensate pipe diameter (in) | 3/4" |
| Max. pipe length (m) | 14 |
| Minimum intake temperature (°C) | +10 |
| Evaporator wall clearance (mm) | 4 |
| Protection class (IP) | 44 |
| Refrigerant | R410A / R32 |
| Data | |
|---|---|
| Heating, min.–max. capacity (kW) | 12.5-31.0 |
| Cooling, min.–max. capacity (kW) | 11.2-27.0 |
| Dimensions Height x Length x Width (mm) | 263x1998x886 |
| Weight (kg) | 65 |
| Number of fans (pcs) | 3 |
| Airflow (m³/h) | 4100 |
| Air throw without EYO hood / with EYO hood (m) | 6 />8 |
| Noise level (SPL)* (dB(A)) | 47/43 |
| Power supply (V/Hz) | 230/50 |
| Maximum operating current (A) | 2.19 |
| Fan power input (W) | 120 |
| Pipe diameter (in) | 1/2” - 1 1/8” |
| Condensate pipe diameter (in) | 3/4” |
| Max. pipe length (m) | 30 |
| Minimum intake temperature (°C) | +10 |
| Evaporator wall clearance (mm) | 4 |
| Protection class (IP) | 44 |
| Refrigerant | R410A / R32 |
Data comes from the EKO2ŠILUMA product database based on manufacturer documentation. Before ordering, we check the current manufacturer specification.
See how it works
IDH-D – 3D diagram
Interactive model: rotate, zoom, click on components.
Documents
Documents will be sent on request.
Installation and commissioning
Where already installed
Descriptions of completed projects with this equipment are published with the client’s consent. Projects
FAQ
Why choose an air-to-air heat pump?
An air-to-air heat pump combines three functions in one system: heating in winter, cooling in summer and air filtration. It can be fitted in an occupied home or a new build, and both the outdoor and indoor units take up little space.
It works well alongside existing heating – electric heaters, a fireplace, a stove or a gas boiler – and takes over much of the heating load in spring and autumn. Some series, such as MSZ-LN, have a more advanced filter system; see the product page for the exact features. We will match the right model to your rooms through the system finder.
Does a heat pump work below −25 °C, and does it harm the unit?
A heat pump keeps working at very low temperatures, but its heat output and efficiency fall. The exact operating limits of each model, per manufacturer data, are on the product page – e.g. MSZ-LN-VGHZ with Hyper Heating or the ZUBADAN PUHZ-SHW series. Operating limit and guaranteed capacity are not the same thing – we explain this in Heat pumps for the Lithuanian climate.
Do not switch the heat pump off during hard frosts: starting a cold system at −25 °C or below is not ideal, while continuous operation is easier on the compressor.
Get a quotation for IDH-D
An engineer will check whether this model suits your building, select the capacity and prepare a quotation including installation and commissioning.


.webp)