Technical data
| Data | |
|---|---|
| (A) Pdesign / SCOP 35°C | 11 / A+++ / 5.08 / 203 |
| Nominal COP 0/35 | 5/ 4.78 |
| Maximum heating capacity 0/35 | 1.5 -11 |
| COOLANT (brine) circuit | |
| System pressure (max.) (MPa) | 1.0 |
| Flow (min. / max.) (l/s) | 0.12 / 0.46 |
| Inlet temperature (min. / max.) (°C) | -8 / +30 |
| Discharge temperature (min.) (°C) | -12 |
| Coolant (bioethanol) | 29% |
| HEATING circuit | |
| System pressure (max.) (MPa) | 0.3 |
| Available external head at nominal flow (kPa) | 40 |
| Heating system temperature (min. / max.) (°C) | 20-60 |
| Plumbing CONNECTIONS | |
| Cold water connection (mm) | 22 |
| Hot water connection (mm) | 22 |
| Borehole return connection (mm) | 28 |
| Borehole flow connection (mm) | 28 |
| WATER CYLINDER | |
| Rated domestic hot water volume (l) | 170 |
| Maximum water pressure (MPa) | 10 |
| Hot water volume at 40 (°C) | 240 |
| Dimensions (mm) (Length x Height x Depth) | 595 X 1750 X 680 |
| Minimum room height (mm) | 1870 |
| Weight (kg) | 181 |
| Compressor module weight (kg) | 70 |
| Sound pressure level (SPL) (dB(A)) | 33-47 |
| Electric heater fuse (A) | 3+6 ,3x16 |
| Compressor operating current (max.) (A) | 10 |
| Operating current (A) | 13 |
| Power supply (V/Ph/Hz) | 400/3/ 50 |
| Recommended fuse (A) | 3x16 |
Specification text for the project
For architects and designers: copy the verified model specification.
Create specificationSee how it works
EHGT17D-YM9ED – 3D
Interactive model: rotate, zoom, click on components.
Start your climate project
Answer a few questions – an EKO2 engineer will assess the site and prepare a quotation covering equipment, installation and commissioning.


.webp)



















.webp)